Soluciones de cableado para transporte ferroviario: bridas para cables y accesorios de cableado KSS aprobados conforme a EN 45545-2 para interiores, exteriores y aplicaciones bajo bastidor
KSS (Kai Suh Suh Enterprise Co., Ltd.) was founded in 1969 and is a global leader in wiring accessories. Its products are sold in 128 countries to more than 40,000 customers, and KSS is one of Asia's largest manufacturers of cable ties and wiring accessories. Its dedicated R&D and production park covers 500,000 square meters, with in-house R&D, design and tooling, and daily cable tie output can reach 50,000,000 pieces. This scale and quality management support rail transit supply chains worldwide.
1. The Challenge: Fire Safety in an Enclosed Vehicle Allows No Compromise
Rail vehicles spend long periods in tunnels and on viaducts. If a fire breaks out, evacuation and rescue are far harder than for most other forms of transport. Flame retardancy, low smoke and low toxicity of interior materials and cable accessories are therefore among the most basic and least negotiable requirements in rail procurement. Four realities shape the selection of wiring accessories:
|
Key term |
Industry requirement |
Explanation |
|
HL1 to HL3 |
Hazard level classification |
EU EN 45545-2 grades fire risk as HL1, HL2 or HL3 based on burning behavior, heat release, smoke density and toxicity. A higher level means a stricter requirement |
|
R22 / R23 |
Interior / exterior application classes |
Wiring accessories such as cable ties are assessed under R22 (interior) or R23 (exterior) according to where they are installed, each with its own thresholds |
|
Local standards |
Parallel standards in mainland China |
Mainland China EMU and urban rail markets also use local standards and product approval schemes (for example TB/T 3237 for EMU interior material flame retardancy, and CRCC product certification). Their test methods and pass criteria differ from EN 45545 |
|
Service life |
Long-term reliability |
Vehicles stay in service for many years with limited maintenance windows, so bundling and protection materials must withstand long-term vibration, temperature cycling and abrasion |
Sources: public technical information on EN 45545-2 and the technical data pages of the KSS factory catalog.
2. The KSS Range: Interior, Exterior and Underframe
Rail vehicle wiring is a complete process, from bundling and routing to cable protection and terminations. The KSS catalog series map to it as follows:
|
Application area |
KSS series |
Example parts |
Key characteristics |
|
Bundling in the vehicle interior |
Flame-retardant nylon cable ties (EN 45545-2) |
CV standard, CV-W UV-resistant, CV-V0 flame retardant, CV-N612 weather resistant |
All four material grades reach HL2 for interior use (R22); the UV-resistant grade reaches HL3 for exterior use (R23) |
|
Interior and control cabinet routing |
Insulating wiring duct |
SD, SDH, UD, MD, KD, HVD, KVD series |
Aligned slots; cut and join at any angle for a tidy panel |
|
Underframe boxes and cable protection |
Conduit + cable glands |
CR-P, MCR metal flexible conduit, NBG series + AG / EG series glands |
Watertight and dust-tight entry for underframe vibration and outdoor exposure |
|
Circuit numbering and terminations |
Wire markers + terminals |
EC / FM / OM / MS series + ET European-style ferrules, R / Y bare terminals |
Circuit traceability plus crimped terminations for reliable contacts |
|
Fixing at special positions |
Mounts, clips and clamps |
HC, KUC, UC, NC / NF / NU series |
Dedicated fixings for blinds, luggage racks, toilets and other interior fittings |
For full part numbers and specifications, see the KSS Rail Transit product list (Excel).
3. EN 45545-2 in Detail: Four Material Grades x Hazard Levels
KSS cable ties hold EU EN 45545-2 rail safety approval. By material grade, the hazard levels for R22 (interior) and R23 (exterior) are:
|
Material grade |
R22 (interior) |
R23 (exterior) |
|
Nylon 66 (standard) |
HL2 |
HL2 |
|
Nylon 66 (UV resistant) |
HL2 |
HL3 |
|
Nylon 66 (flame retardant V0) |
HL2 |
HL2 |
|
Nylon 612 (CV-N612 weather resistant) |
HL2 |
HL2 |
How to read this table:
All four grades reach HL2 for interior use (R22). The UV-resistant grade reaches the highest level, HL3, for exterior use (R23), which makes it the first choice for externally exposed positions. Note also that the V0 grade, the highest UL94 class, is still HL2 for exterior use under EN 45545-2. The two systems are independent: 94V-0 does not mean a higher HL, so each must be checked separately.
Certification coverage varies by specific model and SKU. For the full certification list, refer to the KSS factory catalog, and confirm the approved part numbers and certificates for your project with our sales team.
4. Material Specifications: Temperature, UL94 and EN 45545-2 Side by Side
Besides the EN 45545-2 level, the material grade also sets the temperature range and general flame rating of a cable tie:
|
Material grade |
Series |
Operating temperature |
UL94 rating |
EN 45545-2 (R22 / R23) |
Catalog page |
|
Nylon 66 standard |
CV / CVT |
-40 to 85°C |
94V-2 |
HL2 / HL2 |
P.64-65 |
|
Nylon 66 UV resistant |
CV-W |
-40 to 85°C |
94V-2 |
HL2 / HL3 |
P.72-73 |
|
Nylon 66 flame retardant |
CV-V0 |
As marked in the catalog |
94V-0 |
HL2 / HL2 |
P.69 |
|
Nylon 612 weather resistant |
CV-N612 |
As marked in the catalog |
HB |
HL2 / HL2 |
P.68 |
|
Nylon 46 high temperature |
CV-N46 |
Up to 150°C |
94V-2 |
Not an EN 45545-2 approved item |
P.67 |
Selection note:
For hot positions around underframe equipment boxes, the high-temperature CV-N46 (up to 150°C) can be considered. It is a general industrial grade and is not part of the EN 45545-2 approval above, so please check with our sales team if that position has an EN 45545-2 requirement. UL94 ratings run from HB (lowest) through V2 and V1 to V0 (highest); UL94 and EN 45545-2 are different systems.
5. Proven in Service: Rail Deployment Records
KSS wiring accessories are in service on metro, high-speed rail and airport rail lines, where long-term operation has confirmed their reliability. The part numbers below come from actual KSS project records and are provided as a selection reference:
• Metro system 1: insulating sleeving V3.5 / V5.5 / V14 / V38 / V60, NC cable clips NC8N / NC9N, R / Y terminals R3.5-5 / Y5.5-6, nylon cable ties CV250 / CV550LBK, stainless steel cable ties ASTN300 / ASTN450
• Metro system 2: adhesive-lined heat shrink tubing W3F2-1/4, insulating wiring duct KD1A, releasable cable ties RCV300 / RCV405XL / RCV580XL, extra-wide cable ties CV880XLBK
• High-speed rail: security marker ties SCT250 (lost property identification)
• Airport rail line: outside-serrated cable ties RRCV series, marker plates MS135 / MS100, wiring duct HVD, glands EG series, terminals CL60-12 (lift application)
Tunnel projects and railway authority projects are also covered.
6. Selection by Position: Four Areas of the Vehicle
• Vehicle interior: use cable ties that reach HL2 for interior use (R22) under EN 45545-2; fix blinds, luggage racks and toilet areas with HC / KUC / UC mounts and NC clips.
• Control cabinets: plan routing with SD / MD / KD / HVD insulating duct, number circuits with EC / FM wire markers and terminate with ET European-style ferrules.
• Underframe equipment boxes: use conduit (CR-P, MCR metal flexible conduit) with AG / EG series glands for watertight, dust-tight cable entry; confirm material and approval requirements separately for hot positions.
• Vehicle exterior: give priority to the UV-resistant grade that reaches HL3 for R23, and check every part number against the HL level set for the project.
7. Why KSS
• Two approval systems: EN 45545-2 (R22 / R23) and UL94, with material grades matched to interior and exterior hazard levels.
• Breadth across the vehicle: flame-retardant cable ties, insulating duct, metal conduit and stainless steel cable ties cover interior, exterior and underframe wiring end to end.
• Proven in rail service: deployed on metro, high-speed rail and airport rail lines, with long-term operation confirming reliability.
• Local technical service: Jwo Yiih Enterprise provides selection advice, certification documents and delivery coordination, connected to the KSS supply network serving 128 countries and more than 40,000 customers.
8. Contact
For certification documents, samples or the full part number list for KSS rail transit products, please contact us. We will connect you with KSS factory technical and certification data.
Jwo Yiih Enterprise CO., LTD.
Contact us at sales@jwoyiih.com or call +886-4-8760280 for the full solution package and part number list.
Service scope: technical consultation and quotation on wiring accessories for rolling stock manufacturers, system integrators and maintenance operators
Note: part numbers, materials, flame ratings and page numbers in this article are taken from the KSS factory catalog (page numbers are printed catalog pages) and the KSS Rail Transit product list. The EN 45545-2 material grade x HL table is taken from the approvals page of the KSS rail transit industry presentation, and the deployment part numbers come from actual KSS project records. Operating temperatures for CV-V0 and CV-N612, and EN 45545-2 certificate coverage for each part, vary by specific model and SKU. For a formal quotation or certification documents, please confirm current part numbers and valid certificates with our sales team.